Couldn't load pickup availability
Deliver transformative skin resurfacing results with this professional-grade CO2 fractional laser machine engineered for advanced wrinkle removal, stretch mark reduction, and comprehensive scar treatment. Utilizing precision fractional laser technology, this clinical beauty device provides medical-grade skin rejuvenation, tightening, and anti-aging treatments for professional aesthetic practices and medical spas.
Professional medical spas and aesthetic clinics offering advanced skin resurfacing, dermatology practices providing laser wrinkle reduction services, anti-aging treatment centers specializing in skin rejuvenation, scar revision and stretch mark treatment facilities, skin tightening specialists seeking clinical-grade equipment, upgrading existing laser systems with latest fractional technology, practitioners requiring versatile multi-treatment capabilities, establishing premium aesthetic service offerings.
This is a professional-grade medical device requiring proper training, certification, and licensing for safe operation. Cleanse and prepare the treatment area according to clinical protocols. Apply topical anesthetic 30-60 minutes before treatment for patient comfort. Configure laser parameters based on skin type, Fitzpatrick scale, concern severity, and treatment area. Perform test spot to verify appropriate settings. Deliver fractional laser treatment in systematic overlapping pattern across target area. Apply immediate post-treatment cooling and protective barrier products. Provide comprehensive aftercare instructions including gentle cleansing, intensive moisturizing, and strict broad-spectrum sun protection. The rust-resistant metal and steel construction ensures reliable performance through thousands of professional treatments.
| Product Type | Professional CO2 Fractional Laser Machine |
| Technology | CO2 Fractional Laser Resurfacing System |
| Primary Applications | Wrinkle Removal, Stretch Mark Reduction, Scar Treatment, Skin Tightening, Anti-Aging, Skin Rejuvenation |
| Treatment Areas | Face, Neck, Décolletage, Abdomen, Thighs, Body (Stretch Marks, Scars) |
| Construction | Rust-Resistant Metal and Steel Housing |
| LED Features | Energy-Efficient Precision Lighting System |
| Voltage | 220V |
| Weight | 63.93 lb |
| Use Level | Professional/Clinical Use Only - Requires Certification |
| Durability | Built for Daily Professional Use |
Clean exterior surfaces with mild soap and water after each use. Sanitize handpiece and treatment tips according to medical device sterilization protocols. Dry all components immediately to prevent water spots and maintain rust-resistant finish. Polish metal surfaces occasionally for professional appearance. Follow manufacturer maintenance schedule for laser calibration, safety checks, and performance verification. Store in clean, dry clinical environment with controlled temperature and humidity. Ensure proper ventilation during operation to manage laser plume and maintain air quality.





















A: This medical-grade device requires comprehensive certification and training. Operators must be licensed medical professionals, trained aestheticians, or certified laser technicians with education in laser physics, skin anatomy, treatment protocols, safety procedures, and emergency response. Most regions mandate specific laser safety certification. Manufacturer-provided training, hands-on practice, and ongoing continuing education are essential for safe, effective treatments and optimal patient outcomes.
A: This professional laser treats deep wrinkles and fine lines, pregnancy and weight-loss stretch marks, acne scars and surgical scars, sun damage and age spots, skin laxity and sagging, uneven texture and enlarged pores, hyperpigmentation and melasma, and overall skin aging. The fractional technology allows customizable treatment depth, density, and intensity for various concerns and Fitzpatrick skin types, making it one of the most versatile professional resurfacing devices available.
A: CO2 fractional lasers create thousands of microscopic thermal treatment zones penetrating deep into the dermis while leaving surrounding tissue intact. This fractional approach triggers the body's natural wound-healing cascade, stimulating robust new collagen and elastin production. The controlled thermal damage vaporizes damaged skin layers and promotes accelerated cellular regeneration, resulting in smoother, tighter, more youthful skin. The fractional pattern allows significantly faster healing compared to traditional full-field CO2 resurfacing.
A: Downtime varies based on treatment aggressiveness and individual healing capacity. Light fractional treatments may have 3-5 days of redness and mild flaking, while aggressive deep resurfacing can require 7-14 days of recovery. Patients typically experience redness, swelling, bronzing, and skin peeling as damaged tissue sheds and regenerates. Proper post-treatment care including gentle cleansing, intensive moisturizing, and strict broad-spectrum SPF 50+ sun protection is essential. Most patients can resume normal activities within one week with mineral makeup coverage.
A: Treatment protocols vary by concern severity and desired outcome. Many patients achieve significant improvement after a single aggressive treatment, while others benefit from a series of 2-4 lighter treatments spaced 4-8 weeks apart. Wrinkle reduction and skin tightening results appear gradually over 3-6 months as new collagen matures. Scar and stretch mark improvement typically requires multiple sessions for optimal correction. Maintenance treatments every 12-24 months help sustain long-term results and address ongoing aging.
A: CO2 fractional lasers can be used on various skin types with proper protocols, but darker skin tones (Fitzpatrick IV-VI) carry elevated risk of post-inflammatory hyperpigmentation. Successful treatment requires meticulous patient selection, conservative energy settings, comprehensive pre-treatment preparation with hydroquinone or kojic acid, test spots, and rigorous post-care with brightening agents and sun protection. Some darker-skinned patients may be better candidates for non-ablative alternatives. Always assess individual risk-benefit ratio.
A: This professional CO2 fractional laser operates on 220V power, standard in international markets including Europe, Asia, Australia, Middle East, and parts of South America. If you are located in regions with different voltage standards such as 110V-120V North America, you will require appropriate electrical conversion, dedicated circuit installation, or a model specifically engineered for your local power specifications. Always verify electrical compatibility and consult a licensed electrician before installation.
A: Regular maintenance is critical for patient safety and treatment efficacy. Clean and sanitize handpieces after each use following medical device sterilization protocols. Schedule annual professional calibration, safety inspections, and performance verification. Replace consumable parts like treatment tips and filters according to manufacturer guidelines or usage thresholds. Keep the rust-resistant metal housing clean and polished. Ensure proper ventilation systems function correctly to manage laser plume. Maintain detailed service logs, treatment records, and follow all manufacturer maintenance schedules to ensure reliable operation, regulatory compliance, and patient safety.